PROFIL

 

SUPER THERM®

 

POTVRDA

 

REFERENCA

 

KONTAKT

Thermal tutorial:

Do we really understand heat? To understand insulation and how unique products like Super Therm® work, we must understand the basics, like heat follows cold and more. Read this tutorial to increase your knowledge. This tutorial is simply intended to give some of the basics of heat energy, and how it relates to insulation and ceramic coatings. It is not intended to be comprehensive.

How does heat move?

There are three basic types of heat transfer: conduction, convection, and radiation.

Conduction:

  • Energy transfer through solid objects.
  • Different types of solids transmit heat differently than others, with metals being among the best for heat transfer, and ceramics being some of the most resistant.
  • Example: heat from a cast iron frying pan moves through the handle to your hand.

Convection:

  • Energy transfer through the movement of gases or liquids.
  • Most of heat energy transferred in this manner occurs when heated gases start moving, forming currents that carry the energy from one location to another.
  • Example: forced air heating uses convection to heat a room.

Radiation:

  • Energy transferred through electromagnetic waves.
  • Air absorbs very little energy from radiation. When radiative energy strikes a solid surface, it heats the surface, and the energy is converted to conduction.
  • Example: energy from the sun is in the form of radiation, which is the largest source of heat gain in a building.

Super Therm® works against all three forms of heat transfer. It is most effective against radiation, as it reflects over 95% of the energy from the sun.

Super Therm® fights convection because it allows no air movement through the coating, while avoiding taking up any heat from the air itself.

Only Super Therm® resists heat transfer through conduction as well, due to the unique ceramics used to resist the movement of heat through the coating itself.

Also note that energy is constantly being converted from one heat transfer method to another. Using an uninsulated roof can demonstrate this quite nicely:

  • Energy comes down from the sun in the form of radiation.
  • A small amount of heat is absorbed by the air, transforming it into convective heat.
  • When the radiation from the sun and the convective heat from the air come in contact with a roof, they heat the surface converting this energy into conductive heat transfer, which heats the metal. Super Therm® coated on a roof prevents this from happening, by reflecting the suns energy before it reaches the metal underneath.
  • As the metal gains heat, it heats the air inside the building, forming air convection currents. In this way, heat builds up underneath the roof, and eventually the entire building.
  • When Super Therm® is used, the metal doesn't have a chance to heat up, and thus the building remains cool.

Where does heat move?

A simple rule for the direction of transfer of heat is this: Heat follows cold..

  • Heat always follows the path of least resistance: whichever direction is cooler is the direction the heat will move.
  • What this means is that if there are two objects with different temperatures, the hotter object will always transfer heat to the colder object.
  • For example, when the temperature on one side of a roof is hotter than the other, heat is transferred, through conduction, from the hot side to the cool side through the roof until the temperatures are equal.
  • The belief that heat rises is only true in one circumstance: heated air will rise as it forms convection currents. Heat energy itself normally moves in the path with the least energy (the coldest surface), whether it be up, down, or sideways.

What is R-value?

The R-value is simply a measure of how well a conventional insulation resists heat transfer through conduction only. The greater the value, the greater the ability of the insulation to resist and absorb conductive heat.

A little bit of history: The R-value system was originally developed when the first mass insulation, fibreglass, was first developed, to give a rating for it's ability to resist and absorb heat.

  • When the tests were put into place, they were designed to measure the properties of fibreglass, and to ensure that the highest results would be obtained.
  • The tests were all done under very specific and controlled conditions with regard to the difference in temperature, humidity of the material, and an absence of air movement.

How does conventional insulation work?

  • Normal insulations, including fibre-based (fibreglass, cellulose, etc.) or solid insulation (polyurethane foam, SM board, etc.) contains small pockets of gases, usually air.
  • Heat is transferred slowly through most gases, and thus through the insulation. The pockets of air are small enough that convection currents do not develop inside of the pockets, and thus the heat moves very slowly.The smaller the air pockets, the greater the resistance to heat transfer and thus the greater the R-value. This is why different insulations have different values.
  • As a side effect, insulations absorb heat as it moves from the hot side to the cold side of the material.

For example, an air conditioned building in the summer:

  • The warm temperatures outside of the building are always attempting to penetrate into the cooler areas inside the building.
  • Insulation in the building resists this heat transfer, slowly absorbing the heat until it is either saturated, or the temperature difference decreases.
  • Once saturated, the heat passes through the insulation into the cooler area.
  • In the evening, when the outside temperature decreases, the heat begins transferring from the warmer insulation, to the cooler air outside of the building.

The downside of R-value testing:

The R-value system only accounts for the abilities of insulation against conduction. Against the other two forms of heat transfer (convection and radiation) the effectiveness varies greatly depending on the type of insulation.

For fibreglass, the results of these tests change dramatically under even slightly different conditions:

  • If 1.5% humidity is introduced, fibreglass loses roughly 35% of it's R-value, due the fact that water is a much better conductor than air.
  • All tests are done only at temperatures in which fibreglass would perform best. Above and below this temperature fibreglass rapidly loses effectiveness and the R-value is lower.
  • Air movement also greatly affects the R-value of fibreglass, as heated air moving through the fibreglass drastically reduces it's conductive value.

R-value testing methods do not reflect real world conditions, which can vary greatly with regard to all of these factors: material humidity, temperature differences, and air movement.

Unfortunately these same tests are still used today, despite the fact that new insulations have been introduced into the market. Solid insulations are even more effective than their R-value would suggest, as they are completely unaffected by humidity, temperature, and air movement, as well as having long-term thermal resistance. Super Therm®'s performance is not affected by moisture or air movement

Another downfall is radiation is not accounted for in R-value testing. If stopping radiation was included in R-value testing, Super Therm® would outperform all other insulation.

How is Super Therm® different?

Super Therm® works against all three forms of heat transfer. It is most effective against radiation, as it reflects over 95% of the energy from the sun.

Super Therm® fights convection because it allows no air movement through the coating, while avoiding taking up any heat from the air itself.

Only Super Therm® resists heat transfer through conduction as well, due to the unique ceramics used to resist the movement of heat through the coating itself.

This simply means that heat never builds up. Normal insulations resist and store heat, thus preventing it from passing through the bulk.

Super Therm® stops heat movement so effectively that heat hardly builds up at all. It strongly resists any energy movement through radiation, conduction and convection, through its unique blend of ceramics.

How can ceramic coatings help you?

Lower energy costs, as air conditioners need to work less to dispel heat that never has a chance to collect.

Less heat stress on personnel and livestock, equals increased productivity. A longer lifespan for the surface it is coated on, as the metal itself is protected from expansion and contraction due to the rapid heating and cooling cycles during the days.

The coatings themselves protect against weathering and damage from the environment. Super Therm® will provide 20 years of protection.

How to choose insulation?

Basically, the energy costs must be examined:

If heating costs in the winter are considerably less than the cooling costs in the summer, Super Therm® is the choice. This is especially true where heating is not an issue: in coolers, freezers, and arenas where the sole objective is to maintain a low temperature.

Insulation against frost:

If you need to insulate building against frost or cold - here will help common insulation. But better use solid foam insulation rather than glass-wool or another moisture absorbing material. Pay attention to foam insulation not to stifle Your house, therefore it has to be vapour-permeable, otherwise you wiil get heat in house but moisture and mildew too.

Most sophisticated high-vapour-permeable foam insulation on market is STYREXON (www.styrexon.sk).

We use STYREXON insulation in our combined systems for northern regions with colder weather. You will find more about in section COMBINED SYSTEMS.

Objašnjenja (osnovnih pojmova):

Zračenje - Proces pri kome je toplota zračena iz tijela kroz otvoreni prostor pomoću zrakova, primjerice sunčevo zračenje.

Toplota - razina toplote je mjerena u stupnjevima Celzija (°C), teplotne razlike su mjerene u Kelvinima (K).

Prodor zraka - prodor zraka u zgradu preko šupljina ili strukture materijala.

Kondenzacija - Kondenzacija je promjena pare iz plinovitog stanja u tekuće stanje pri dodiru s hladnom površinom.

Provodnost - Prijelaz topline uzdužno ili iz materijala u drugi materijal kojeg se dotiče.

Strujanje - Prijenos toplote kretanjem zraka.

Absorbivnost - sposobnost primati u sebe dolazeće sunčevo zračenje.

Emisivnost - može se definirati na dva načina, kao:

  • Absorpcijska emisivnost: (sposobnost održavati toplotno zračenje), sa navodi kao mjera zračenja oslobađana sa površine. Materijali s mat crnom površinom imaju visoku emisivnost koja se približava maksimalnoj granici od 1,0, zadržavaju veliki obim zračenja. I obrnuto, tijela sa sjajnom površinom kao što su zrcala ili lašteni aluminij, imaju nisku emisivnost od 0,08, dakle ne zadržavaju u sebi skoro nikakvo zračenje. Super Therm® ima sasvim najnižu vrijednost emisivnosti od 0.05.
  • Infracrvena emisivnost: (sposobnost lišiti se topline – izračiti je), se isto tako navodi kao mjera zračenja, oslobađana sa površine. Infracrvenu zračnu emisivnost posjeduje Super Therm® vrlo visoku (više od 95%/vrijednost 0,95), a šta znači da je ekstremno ulčinkoviti u ispuštanju i one male količine topline koju je absorbirao.

Toplotni gubitak - Prijenos topline iz unutarnjih prostora u vanjske prostore pomoću provodnosti, strujanja i zračenja.

Toplotna provodnost - omjer u kome toplina prolazi kroz materijale, mjeri se u Watima na metar kvadratni površine za toplotni stupanj jednog Kelvina na metar debljine, jednostavnije definirano kao W/m.K.

Teplotna masa - je masa zgrade koja se rabi za absorbiranje solarne topline u toku dana, a onda se navečer oslobađa.

Mjerni toplotni otpor - R- toplotni otpor je fizikalna veličina koja izražava termoizolacijske osobine konstrukcije. Ciljem je postizanje što veće R vrijednosti. Toplotni otpor R izražava otpor 1 m2 konstrukcije prijelaza toplotne energije pri razlici toplota od 1 K.

Paropropustni materijal - Paropropustni materijal spriječava prodor vode, no pri tome „diše“, dakle propušta vodne pare.

VRH